1 Scope
This part of IEC 60317 specifies the requirements of enamelled rectangular copper winding wire of class 120 with a dual coating. The underlying coating is based on polyvinyl acetal resin, which can be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. The second coating is a bonding layer based on a thermoplastic or thermosetting resin. NOTE A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics. The range of nominal conductor dimensions covered by this document is: – width: min.2,00 mm max.16,00 mm; . thickness: . min.0,80 mm max. 5,60 mm. Wires of grade 1 and grade 2 are included in this specification and apply to the complete range of conductors. The specified combinations of nominal width and thickness as well as the specified ratio width/thickness are given in IEC 60317-0-2:2019.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60317-0-2:20191, Specifications for particular types of winding wires – Part 0-2: General requirements – Enamelled rectangular copper wire IEC 60851-4:2016, Winding wires – Test methods – Part 4: Chemical properties
3 Terms, definitions, general notes and appearance
3.1 Terms and definitions For the purposes of this document, the terms and definitions given in IEC 60317-0-2:2019 apply. ISO and IEC maintain terminological databases for use in standardization at the following addresses: 3.2 General notes 3.2.1 Methods of test Subclause 3.2.1 of IEC 60317-0-2:2019 applies. In case of inconsistencies between IEC 60317- 0-2:2019 and this part of IEC 60317, this document IEC 6031 7-80 shall prevail. 3.2.2. Winding wire Class 120 is a thermal class that requires a minimum temperature index of 120 and a heat shock temperature of at least 155 °C. The temperature in degrees Celsius corresponding to the temperature index is not necessarily that at which it is recommended that the wire be operated and this will depend on many factors, including the type of equipment involved.
9 Heat shock
Clause 9 of IEC 60317-0-2:2019 applies, where the minimum heat shock temperature shall be 155 °C.
10 Cut-through
Test requirements under consideration.,
11 Resistance to abrasion
Test inappropriate.
12 Resistance to solvents
Test requirements under consideration.
13 Breakdown voltage
Clause 13 of IEC 60317-0-2:2019 applies, where the elevated temperature shall be 120 °C.
14 Continuity of insulation
T est inappropriate.
15 Temperature index
Clause 15 of IEC 60317-0-2:2019 applies, where the minimum temperature index shall be 120.