IEC 62031:2018 pdf download.LED modules for general lighting – Safety specifications
1 Scope
This document specifies general and safety requirements for light-emitting diode (LED) modules: • non-integrated LED modules (LEDni modules) and semi-integrated LED modules (LEDsi modules) for operation under constant voltage, constant current or constant power; • Integrated LED modules (LEDi modules) for use on DC supplies up to 250 V or AC supplies up to 1 000 V at 50 Hz or 60 Hz. LED modules within the scope of this document can be integral, built-in or independent. This document is not applicable for LED lamps. NOTE The performance requirements for LED modules are specified in IEC 6271 7.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60598-1 :201 4, Luminaires – Part 1: General requirements and tests IEC 60598-1 :201 4/AMD1 :201 7 IEC 61 032:1 997, Protection of persons and equipment by enclosures – Probes for verification IEC 61 347-1 :201 5, Lamp controlgear – Part 1: General and safety requirements IEC 61 347-1 :201 5/AMD1 :201 7 IEC 62471 :2006, Photobiological safety of lamps and lamp systems IEC 62504, General lighting – Light emitting diode (LED) products and related equipment – Terms and definitions IEC TR 62778:201 4, Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires ISO 4046-4:201 6, Paper, board, pulp and related terms – Vocabulary – Part 4: Paper and board grades and converted products ISO 7089:2000, Plain washers – Normal series – Product grade A
3 Terms and definitions
For the purposes of this document, the terms and definitions given in IEC 62504 and the following apply.3.2 replaceable LED module LED module, designed to be replaced by an ordinary person or a qualified person Note 1 to entry: When incorporated into a luminaire, a replaceable LED module can be classified as replaceable, non-user replaceable or non-replaceable depending on the luminaire design. 3.3 non-replaceable LED module LED module designed to be a non-replaceable part of the luminaire Note 1 to entry: An integral LED module is always non-replaceable. A non-replaceable LED module is not always an integral LED module. Note 2 to entry: The non-replaceability can be the result of the luminaire design. 3.4 non-user replaceable LED module LED module designed to be replaced only by the manufacturer, his service agent, or similar qualified person Note 1 to entry: When incorporated into a luminaire a non-user replaceable LED module can become classified as non-replaceable depending on the luminaire design. 3.5 terminal conductive part of an LED module, provided for connecting that LED module to one or more external conductors [SOURCE: IEC 60050-1 51 :2001 , 1 51 .1 2.1 2, modified – “device, electric circuit or electric network” has been replaced by “LED module” and the note has been deleted.] 3.6 integral terminal terminal which forms a non-replaceable part of an LED module and which cannot be tested separately from the LED module [SOURCE: IEC 60598-1 :201 4, 1 .2.58, modified – “component” replaced by “terminal”, “luminaire” replaced by “LED module”.]
4 General requirements
4.1 LED modules shall be so designed and constructed that they operate without danger to the user or surroundings when used as intended (see manufacturer’s instructions). NOTE IEC 61 347-1 :201 5, Annex S gives examples of insulation coordination which can be appropriate for LED modules.4.3 For non-integrated LED modules and semi-integrated LED modules, all electrical measurements, unless otherwise specified, shall be carried out at voltage limits (min/max), current limits (min/max) or power limits (min/max) and minimum frequency, in a draught-free room at the temperature limits of the allowed range specified by the manufacturer. Unless the manufacturer indicates the most critical combination, all combinations (min/max) of voltage/current/power and temperature shall be tested. 4.4 For integrated LED modules, the electrical measurements shall be carried out at the tolerance limit values of the rated supply voltage. 4.5 Integral LED modules not having their own enclosure shall be regarded as integral components of luminaires according to IEC 60598-1 :201 4, 0.5.1 . 4.6 In addition to the requirements of this document, independent LED modules shall comply with IEC 60598-1 :201 4 and IEC 60598-1 :201 4/AMD1 :201 7.