Oct,05

IEC 61169-60:2021 pdf download

IEC 61169-60:2021 pdf download

IEC 61169-60:2021 pdf download.Radio-frequency connectors – Part 60: Sectional specification for RF coaxial connectors with push on mating
1 Scope
This part of IEC 61169, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for RF coaxial connectors with push-on coupling, typically for use in 50 Ω RF cables or micro-strips in microwave, telecommunication, wireless systems and other fields (SMPM). It specifies mating face dimensions for general purpose connectors – grade 2, dimensional details of standard test connectors-grade 0, gauging information and tests selected from IEC 61169-1, applicable to all detail specifications relating to series SMPM RF connectors. This specification indicates recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H. The SMPM push-on coupling structure series RF coaxial connectors with the characteristic of normative impedance 50 Ω are used with various kinds of RF cables or micro-strips in microwave, telecommunication, wireless systems. The operating frequency limit is up to 65 GHz. NOTE Imperial dimensions are original dimensions. All undimensioned pictorial configurations are for reference purpose only.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60068-1, Environmental testing – Part 1: General and guidance IEC 61169-1:2013, Radio frequency connectors – Part 1: Generic specification – General requirements and measuring methods IEC 62037 (all parts), Passive RF and microwave devices, intermodulation level measurement
3 Terms and definitions
No terms and definitions are listed in this document. ISO and IEC maintain terminological databases for use in standardization at the following addresses: IEC Electropedia: available at http://www.electropedia.org/ ISO Online browsing platform: available at http://www.iso.org/obp
5 Quality assessment procedure
5.1 General Clause 10 of IEC 61169-1:2013 applies to this sectional specification, except as follows: Subclauses 5.2 to 5.4 provide rating, performance and test conditions to be considered when writing a detail specification. They also provide an appropriate schedule of tests with minimum levels of conformance inspection sampling. 5.2 Rating and characteristics (see Clause 5 of IEC 61169-1 : 2013) The values indicated below are required for SMPM series RF coaxial connectors unless otherwise stated and are given for the writer of the detail specification. They are applicable for the condition when the connectors are fully mated. Certain tests may not have requirements and this is indicated by a blank or NS (not specified). These requirements shall be specified in the detailed specification by the manufacture of the connector. These ratings and characteristics serve as the input in preparing the detailed specification, describe what shall be mandatory, and what is up to the discretion of the manufacturer. Preferred climatic categories are given in Table 10. Ratings and characteristics are given in Table 11.5.4 Procedures for the quality conformance Quality conformance inspection 5.4.1 This shall consist of test group A1 and B1 on a lot-by-lot basis and test group D1 to D7 on a periodic basis. 5.4.2 Quality conformance and its maintenance This shall consist of three consecutive lots passing test groups A1 and B1 followed by selection of specimens from the lots as appropriate. These specimens shall successfully pass the specified periodic D tests.
6 Instructions for preparation of detail specifications (DS)
6.1 General  Detail specifications writers shall use the appropriate blank detail specification (BDS). The following pages comprise the pro-forma BDS dedicated for use with type 50 Ω type SMPM connectors. As such, it will already have entered on it information relating to: a) the basic specification number applicable to all the detail specifications covering connector styles of the series covered by the sectional specification; b) the connector series designation. The specification writer should enter the details relating to the connector style to be covered as indicated. The number in brackets in the BDS corresponds to the following indications, which shall be given.