Oct,06

IEC 61820-1:2019 pdf download

IEC 61820-1:2019 pdf download

IEC 61820-1:2019 pdf download.Electrical installations for aeronautical ground lighting at aerodromes – Part 1: Fundamental principles
1 Scope
This part of IEC 61 820 covers principles of design and installation requirements for AGL systems including control, monitoring and transformation of energy, the cables and any electrical component utilized to produce the light intended to be used as a visual aid for air and ground navigation. This document defines in general the fundamental principles to provide safe, reliable and efficient operation of AGL systems independent of the particular system design. Where certain aspects of design are specific to a particular type of system (e.g. series-circuit), these are supplemented in the applicable part. NOTE Local / national regulations can be different from the provisions of this document.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60364-4-41 , Low-voltage electrical installations – Part 4-41: Protection for safety – Protection against electric shock IEC 60721 -3-3, Classification of environmental conditions – Part 3: Classification of groups of environmental parameters and their severities – Section 3: Stationary use at weatherprotected locations IEC 60721 -3-4, Classification of environmental conditions – Part 3: Classification of groups of environmental parameters and their severities – Section 4: Stationary use at non- weatherprotected locations IEC 61 000-6-2, Electromagnetic compatibility (EMC) – Part 6-2: Generic standards – Immunity standard for industrial environments IEC 61 000-6-4, Electromagnetic compatibility (EMC) – Part 6-4: Generic standards – Emission standard for industrial environments IEC 62870, Electrical installations for lighting and beaconing of aerodromes –Safety secondary circuits in series circuits – General safety requirements
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminological databases for use in standardization at the following addresses:3.1 AGL aeronautical ground lighting any light specially provided as an aid to air navigation, other than a light displayed on an aircraft Note 1 to entry: This note applies to the French language only. [SOURCE: ICAO Annex 1 4 to the Convention on International Civil Aviation:201 8.] 3.2 lifecycle series of identifiable stages through which an item goes, from its conception to disposal Note 1 to entry: See IEC TS 621 43 for AGL systems lifecycle. 3.3 electric insulation part of an electrotechnichal product which separates conducting parts at different electric potentials during operation or insulates such parts from the surroundings [SOURCE: IEC 60050-21 2:201 0, 21 2-1 1 -07] 3.4 insulation resistance resistance under specified conditions between two conductive elements separated by insulating materials [SOURCE: IEC 60050-1 51 :2001 , 1 51 -1 5-43] 3.5 insulation monitoring continuous determination of the state or condition of the system electrical insulation 3.6 equipotentiality state when conductive parts are at a substantially equal electric potential [SOURCE: IEC 60050-1 95:1 998, 1 95-01 -09] 3.7 equipotential bonding provision of electric connections between conductive parts, intended to achieve equipotentiality [SOURCE: IEC 60050-1 95:1 998, 1 95-01 -1 0] 3.8 field circuit isolator device which provides, in the dedicated position, an isolating distance between the power supply and cables feeding AGL loads 3.9 load, noun device intended to absorb power supplied by another device or an electric power system3.1 1 nominal voltage value of the voltage by which the electrical installation or part of the electrical installation is designated and identified [SOURCE: IEC 60050-826:2004, 826-1 1 -01 ] 3.1 2 rated insulation voltage rated value of the rms withstand voltage assigned by the manufacturer to the equipment or to a part of it, characterizing the specified (long-term) withstand capability of its insulation Note 1 to entry: The rated insulation voltage is not necessarily equal to the rated voltage of equipment which is primarily related to functional performance. [SOURCE: IEC 60050-31 2:2001 /AMD1 :201 5, 31 2-06-02] 3.1 3 exposed conductive part conductive part which can readily be touched and which is not normally alive, but which may become alive under fault conditions Note 1 to entry: Typical exposed conductive parts are walls of enclosures, operating handles, etc. [SOURCE: IEC 60050-441 :2000, 441 -1 1 -1 0] 3.1 4 field circuit part of the AGL system that starts from the output terminals of the power source or, if a field circuit isolator is installed, from the output terminals of the field circuit isolator

Download
The previous

IEC 61557-6:2019 pdf download

The next

IEC 61892-4:2019 pdf download

Related Standards