IEC 63086-1:2020 pdf download.Household and similar electrical air cleaning appliances – Methods for measuring the performance
1 Scope
This part of IEC 63086 applies to electrically powered household and similar air cleaners intended for use on rated single-phase AC input voltage circuits not exceeding 250 V and DC input voltage circuits not exceeding 48 V. NOTE 1 See Clause 4 for examples of different technologies and placements of household and similar air cleaners . NOTE 2 If the test methods in this document are applied to combination products (air conditioners, humidifiers, dehumidifiers, heaters, etc.) with air cleaning function, they are only aimed at their air cleaning function when tested. NOTE 3 Battery-operated appliances are within the scope of this document. Dual-supply appliances, either mains- supplied or battery-operated, are regarded as battery-operated appliances when operated in the battery mode. NOTE 4 This document is not applicable to: appliances intended exclusively for industrial purposes; appliances intended for use in medical treatment locations, such as surgical suites, laboratories, medical treatments rooms, etc. • household range hoods or cooking fume extractors – see IEC 61591.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60704 (all parts), Household and similar electrical appliances – Test code for the determination of airborne acoustical noise IEC 62301:2011, Household electrical appliances – Measurement of standby power
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminological databases for use in standardization at the following addresses: IEC Electropedia: available at http://www.electropedia.org/ ISO Online browsing platform: available at http://www.iso.org/obp 3.1 air cleaner electrically powered household, or similar, appliance that employs one or multiple technologies to reduce one or more types of indoor air pollutants 3.2 robotic air cleaner air cleaner that operates and changes its physical location autonomously without user intervention Note 1 to entry: The robotic air cleaner can consist of a part that houses the air cleaning function and can have a docking station and/or other accessories to assist its operation. 3.3 fresh-air air cleaner air cleaner connected to the external environment, which provides pollutant-reduced outdoor air into an indoor space Note 1 to entry: The fresh-air air cleaner can also include other auxiliary functions, such as heat exchange. 3.4 combination products air cleaner that includes a secondary function besides air cleaning within the same housing, such as humidifying, dehumidifying, heating, or air conditioning 3.5 DUT device under test air cleaner undergoing examination 3.6 test chamber self-contained room with determined volume, shape, and dimensions, which is used to measure the performance of the DUT 3.7 target pollutant specific air pollutant with defined components, including three main categories: particulate matter, gaseous pollutants, and microorganisms 3.8 operation decay rate reduction rate of the target pollutant in the test chamber , due to operation of the DUT Note 1 to entry: Units are per hour (h −1 ). 3.9 CADR clean air delivery rate flow rate of clean air (with respect to the target pollutant) delivered by the DUT calculated as the product of the measured operation decay rate and the associated test chamber volume Note 1 to entry: The unit is cubic metres per hour (m 3 h −1 ).3.10 automatic operation mode setting of the DUT chosen by the user in which the performance is regulated by the air cleaner without further user interaction 3.11 manual operation mode setting of the DUT, chosen by the user, that is not influenced by further external operator interaction, air quality sensor data, and/or timers throughout the duration of the test

Download
The previous

IEC 63068-1:2019 pdf download

The next

IEC 63169:2020 pdf download

Related Standards